N2000 – Universal Temperature and Process PID Controller with Ramp and Soak, 1/8 DIN

$204.00 $102.00

  • Shipping Icon
    Free
    Shipping
  • Shipping Icon
    Safe
    Payment
  • Shipping Icon
    Best
    Services
  • Multi-Sensor Universal Input-Thermocouples, RTD, Voltage, Milliamp
  • Relay, 4-20 mA and Logic Pulse Control Outputs
  • Auto-Tune PID Parameters
  • Automatic/Manual Function with BUMPLESS Transfer
  • Four Modes of Independents Alarms, with Functions of Minimum, Maximum, Differential (Deviation), Open Sensor and Event
  • Timer Functions that can be Associated to the Alarms
  • Square Root Extraction
  • Retransmission of PV or SP in 0-20 mA or 4-20 mA
  • Input for Remote Setpoint
  • Digital Input With 5 Functions
  • Programmable Soft-Start
  • 7 Setpoint Profile Programs with 7 Segments Each, with the Ability to be Linked Together for a Total of 49 Segments
  • Optional RS-485 Serial Communication, Modbus RTU Protocol
  • Password for Parameters Protection
  • 24vdc Power Supply for Remote Transmitters

The N2000 is an extraordinarily versatile process controller. It contains in one single instrument all of the features needed for the vast majority of industrial processes. It accepts virtually all industrial sensors and signals and provides output types required for the control of many diverse processes.

From very simple applications as a temperature controller to the most complex systems of distributed control with PLCs or SCADA networks, the N2000 is the right answer for your industrial or laboratory automation needs.

Universal Input
The N2000 can accept most process sensors and signals. It works with thermocouples (J, K, T, E, N, R, S and B), RTDs (PT100)

Up to Seven Outputs
The N2000 has can have up to seven outputs. These include four relay outputs (2 SPST and a SPST), two logic pulse outputs for SSR drive and one analog output which can be used for control or retransmission of the process reading or setpoint. The logic pulse outputs are dual function and may be used as inputs rather than outputs. As inputs they are used in the application of a remote setpoint.

Auto-tune PID Control
You can either set the PID parameters yourself or let the N2000 self configure the parameters by using the Auto-Tune mode. You can also manually set the output. When switching from manual to automatic control “BUMPLESS” transfer occurs which provides a smooth transition of the output when switching modes.

Remote Setpoint
The controller can have its setpoint value defined by an analog, remotely generated signal. The remote setpoint input signals can be 0-20 mA, 4-20 mA, 0-5 V and 0-10 V.

Analog Retransmission of Process Reading and Setpoint
The analog output, when not used for control purposes, is available for retransmitting the the process reading and setpoint values in 0-20 or 4-20 mA. This analog output is electrically isolated from other inputs and outputs.

Auxiliary 24 Vdc Power Supply