Ageon A108 | Differential Temperature Controller Solar/Water/Air (110/240V)

$45.13 $36.10

  • Shipping Icon
    Free
    Shipping
  • Shipping Icon
    Safe
    Payment
  • Shipping Icon
    Best
    Services

The A108 from Ageon is a temperature controller suitable for differential control of pumps, fans and valves. It has two sensors and a relay output for activating circulation according to the temperature difference between the T1 and T2 sensor readings. The instrument contains two NTC-type temperature sensors with 1.5M cable length, and the relay output has 17A capacity for direct switching of loads.

In a solar system, the water pump is activated to send heated water from the collector back to the storage tank. For air destratification/circulation, the control output activates a high-level fan to keep an even temperature throughout the building layers, eliminating heat wasted at the top of a building.

Basic parameters allow setting of differential on and off temperature, with two independent settings for greater control of the output. Advanced parameters allow protection to be set, preventing damage to the system due to low/high temperatures.

Well suited to hot water temperature control (solar installations, swimming pools, hot tubs, and hot water systems), HVAC air destratification (recycling hot air in factories, warehouses, and agricultural buildings), and agriculture (greenhouses, and cooling grain stores to maintain differential).

2 Year Manufacturer Warranty backed by our UK-based technical support

Ageon A108 Manual/Setup Guide

Technical Details

Power: 110 or 220 Vac. Maximum power: 4 VA

Pump relay output: 17 A / 250 Vac

Measuring range: -20 to +105C. Resolution: 0.1C from -20 to +105C

Operating conditions: 0 to 40C, 10-80% RH non-condensing

Dimensions (W x H x D): 93 x 37 x 73mm. Degree of protection of the front part: IP65

NTC sensors: IP68, 5mm / L=20mm, standard length 1.5m

Functions: Standby (control outputs off, display idle), Automatic/Manual control, Differential On/Off individual setpoints, Pump Delay (adjustable 0-20 mins), antifreeze and overheat protections, Pump timeout (adjustable in auto and manual), Indicator mode (read temperatures only), Alarms/Limits (high and low temperature), Sensor Calibration (adjustable offsets)

Frequently Asked Questions

Are the sensors supplied?
Yes the 2 sensors come with the controller. They can also be extended with 2x 0.5mm cable.

How should the sensors be attached?
Use of a thermowell is recommended by the manufacturer, but many customers have successfully attached the probes directly to pipework and reservoirs