  • The A104 model is an automatic electrical temperature controller intended for refrigeration systems. The main output regulates temperature by direct control of the compressor. The A104 is widely used in food and dairy cooling tanks, as it can also control a stirrer function using the secondary output.

    Another major advantage of the A104 is that it contains voltage protection parameters that can detect possible variations in the power line and activate the controller’s protection preventing damage to compressor windings caused by excessive current and heat, prolonging equipment life in areas with an unstable power grid. Adjustable thresholds for minimum and maximum voltage can be set to provide a safe operating window for the compressor.

    The Black Line A104 has an Economy Mode to save energy as well as a thermometer function, plus all the standard Black Line features 6 keys, two ways of fastening (clips and screws), and the option of online monitoring with ArcSys or the Ageon WebFi gateway.

    2 Year Manufacturer Warranty backed by our UK-based technical support

    Ageon A104 Manual Download

    Technical Details

    Power supply: 220 Vac ( 10%). Maximum power: 2 VA

    Relay Outputs: Compressor (10 A / 250 Vac), Stirrer (10 A / 250 Vac) note: the sum of the currents cannot exceed 18 A

    Measuring range: -50 to +100C. Resolution: 0.1C from -50 to +100C

    Operating conditions: 0 to 40C, 10-80% RH non-condensing

    Panel cutout: 70 x 29mm ( 5%). Degree of protection of the front panel: IP65

    NTC sensor: IP68, 6mm / L=15mm, standard length 2.5M

    Frequently Asked Questions

    What does the stirrer output do?
    The secondary relay output can control a motorised stirrer independently of the main compressor control widely used in food and dairy cooling tanks.

    Why would I need voltage monitoring on a temperature controller?
    It protects the compressor from an unstable power grid detecting voltage variations outside your set thresholds and activating protection before excessive current or heat can damage the compressor windings.

    Can I monitor this remotely?
    Yes the A104 supports Ageon’s ArcSys online monitoring, and connectivity can be added via the Ageon WebFi gateway.